What is the life expectancy of flexible air ducts?
Your pressure ratings are different than some flex ducts. Why?
Is your insulation 100% formaldehyde free?
Does JPL flex qualify for the OC Builder Alliance™ Program?
What do you mean by a "Certified" R value?
Are there any flex duct installation precautions with UVC?
What type of product warranty does JPL have?
What is the friction loss for JPL ducts?
Where can I find installation instructions for JPL flexible ducts?
What is the life expectancy of flexible air ducts?
When properly installed per the Air Diffusion Council (ADC) installation instructions (furnished in each package), flexible air ducts should last for the life of the dwelling.
Back to Top
Your pressure ratings are different than some flex ducts. Why?
JPL tests and publishes positive pressures based on results of the ADC FD 72-R1 test method. This method requires a 90-degree elbow of the duct and temperatures up to 180 F. Many of our competitors with higher pressures test the ducts with no bends and at room temperatures.
Back to Top
Is your insulation 100% formaldehyde free?
No, the insulation we use isn't 100% formaldehyde free, but neither is any other fiberglass insulation currently available. JP Lamborn Co. does use however Owens Corning GreenGuard® Indoor Air Quality Certified insulation which has been tested to ensure their chemical & particle emissions meet stringent guidelines and standards.
Back to Top
Does JPL flex qualify for the OC Builder Alliance™ Program?
Yes, we certainly do. As just one of a handful of flex producers who use Owens Corning Pink Insulation exclusively, builders can earn an additional ½ point promotional allowance when using JPL flex duct.
Back to Top
What do you mean by a "Certified" R value?
The R-Value of every JPL insulated flex duct has been verified by a third party inspector at both the insulation manufacturers' plants and our own assembly plants. When purchasing a JPL product with a certified R-Value of R4.2, R6 or R8 you’re assured the R-Value will perform as advertised. Many code jurisdictions now require certified R-Values.
Back to Top
Are there any flex duct installation precautions with UVC?
Yes, the inner core of most flex ducts is susceptible to Ultra Violet light and may become brittle if exposed for long periods of time. JPL suggests 1 foot distance from the UV source on foil back MNI25, 2 feet on all polyester inner cores and 5 feet on AMBlue & AMF-07 installations.
Back to Top
What type of product warranty does JPL have?
JP Lamborn Co. is proud to be one of a few flex duct manufacturers to offer a 10 year limited warranty Download/view warranty PDF file.
Back to Top
What is the friction loss for JPL ducts?
You can use our online Flash Calculator here. Requires free Macromedia Flash player.
Back to Top
Where can I find installation instructions for JPL flexible ducts?
Click here for installation instructions. Further information about proper installation of flexible duct may be found in the Air Diffusion Council's Flexible Duct Performance and Installation Standards also known as the "Green Book"
Back to Top
|